Facility & Utility Systems
Fire Protection
Fire alarms, sprinklers, hydrants, gaseous suppression, fire pumps, extinguishers, smoke control and kitchen suppression: from detection to suppression.

Details
A fire protection system gets tested only once, by a real fire. Unless you test it first.
We handle fire protection from detection to suppression. Fire alarms detect and warn. Sprinklers and hydrants suppress fire with water, foam or water mist, driven by fire pumps. For spaces that must stay dry, such as server rooms, panel rooms and archives, we install gaseous suppression using agents such as FM-200, Novec 1230, CO₂, INERGEN or aerosol. Commercial kitchens get dedicated suppression in their hoods, and multi-storey buildings can be fitted with smoke control and stairwell pressurisation.
We also supply, refill and hydrostatically test fire extinguishers.
Standards you can check
Every system is designed and installed to the NFPA standards that apply to it, including NFPA 72 for alarms, NFPA 13 for sprinklers, NFPA 14 for hydrants, NFPA 20 for fire pumps, NFPA 2001 for gaseous suppression and NFPA 10 for extinguishers, as well as the related SNI standards. Where the project specification requires it, we supply UL-listed or FM-approved equipment.
Systems are tested and commissioned before handover. After that, we carry out regular maintenance and testing so the system stays ready for the day we hope never comes. Official inspections that require certified testing are carried out together with a licensed K3 inspection company (PJK3) under our coordination.
Sub-systems
Fire Alarm System
Detectors, panels and alarms that sense smoke or heat and give early warning.
Sprinkler System
Pipe networks and sprinkler heads that suppress fire automatically where it starts, using water, foam or water mist.
Hydrant System
Building and yard hydrants, with hose boxes, hoses and nozzles for manual firefighting by staff or the fire brigade.
Gaseous Suppression
Gaseous suppression for server rooms, panel rooms and archives that must stay dry: FM-200, Novec 1230, CO₂, INERGEN or aerosol.
Fire Pump
Electric, diesel and jockey fire pumps with their control panels, keeping sprinkler and hydrant pressure ready.
Fire Extinguisher (APAR)
Supply of fire extinguishers suited to each fire risk, plus refilling and hydrostatic testing.
Smoke Control & Stair Pressurization
Stairwell pressurisation fans and smoke extraction that keep evacuation routes smoke-free in multi-storey buildings.
Kitchen Fire Suppression
Automatic suppression in commercial kitchen hoods and ducts, for restaurants, hotels and production kitchens.
Brands & standards
Platforms we use
- Notifier by Honeywell
- Simplex
- System Sensor
- Hochiki
- Nohmi
- Kidde
- Tyco
- Viking
- Victaulic
- Ansul
- Chemguard
- Hygood
- NAFFCO
- SFFECO
- Vigilant
- Kitz
- Weflo
- Grundfos
- Pentair
- Torishima
- Ebara
- Fairbanks Nijhuis
References
- NFPA 72
- NFPA 13
- NFPA 14
- NFPA 20
- NFPA 2001
- NFPA 10
- SNI
- EN 54
